M9131A -
Keysight Technologies
The M9131A is a high-density, general purpose switch with 64 independent, single-pole, double-throw (Form C) switches in a single PXI module. This module can be used to cycle power to products under test, control indicator and status lights, or actuate external power relays and solenoids. The high-speed, long-life reed relays can handle 100 Vrms and 1 A, with up to 3 W maximum power. Choose from the durable connector block or standard cable connections.
-
M9156CH40 -
Keysight Technologies
The Keysight M9156CH40 PXI hybrid dual transfer switch module provides an exceptional 0.03 dB insertion loss repeatability, high isolation, low SWR with a long operating life up to 10 million cycles.
-
M9157C -
Keysight Technologies
M9157C operates from DC to 26.5 GHz, providing a low-cost operation switching solution for measurement and automation of Automatic Test Equipment (ATE) systems without compromise in the RF performance. It is being used in applications such as ATE, RF communication and RF parametric measurements where a rugged switching module is needed for signal routing. Typical switching applications for multiport coaxial switches include signal routing to a single input to multiple instruments and routing of multiple input signals.
-
42-890-006 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-004 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
42-890-002 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
42-890-004 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
42-890-003 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-001 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
42-890-001 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-003 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-005 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-890-006 -
Pickering Interfaces Ltd.
The 40-890 (PXI) and 42-890 (PXIe) range of PXI microwave modules allows users to specify the mix of relay types, frequencies and quantities based on the application requirements within the capabilities of the module driver card. Choose from the extensive relay selection already available in the Pickering microwave range to create a flexible solution.
-
40-192-012 -
Pickering Interfaces Ltd.
This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.
-
150579-01 -
NI
96-Pin Male SCSI to 96-Pin Female SCSI Switch Cable, 1m (protected) - The SH96F-96M SwitchBlock SCSI Cable provides connectivity for SwitchBlock modules. You can connect these to the TBX-2809 Terminal Block, which exposes each channel of the switch module to screw terminals.